- Relationship between Flash Point and Front-end Distillation data of petroleum products, (a Scholarly article)

- Relationship between Flash Point and Front-end Distillation data of petroleum products, 

The relationship between Flash Point and Atmospheric front-end Distillation data of petroleum products, normally recorded during the routine testing are correlated during 1986 – 1988 period by a team (S/S  RJ Patel, PD Dusane, NS Kamble, SK Shukla at IOC Kandla Laboratory ).  The idea was originated from similar literature that time, W.L. Nelson ( Petroleum Engineering, pg 131, edition 1982, initially put forward in year 1944).

Team under the leadership of the author of this blog could work out a most improved/accurate empirical relationship as given below:

Predicted Abel Flash Point  FP = 0.613*IBP + 0.193*T10  -  84.0.


             ( all temperatures  in deg Centigrade, C ).

Where,    FP = Abel Flash Point deg, C
                IBP= Initial Boiling Point as per ASTM D86 Distillation  &
                T10 = ASTM D86 Distillation, 10% recovery temperature

The empirical formula has been derived by testing and further revalidated more than 5000 Kerosene, Aviation Turbine fuel, and  similar samples from products received at Kandla, which were derived  from a wide range of crudes and refineries from Russia, US, Venezuela,  China, Gulf countries, Singapore etc beside India.  The team was benefitted incidentally  since India was importing finished products from a wide global sources during the period mentioned.

Later on, some other work on the same subject appeared and one such very reputed reference is found in API correlation (1997 version).  FP = 0.68*T_10%_D86 - 109.6  where    FP: flash point , ºF,  T_10%_D86 : ASTM D86 10% temperature , ºF.  Also, by D.S.J. Jones (Elements of Petroleum Processing-Wiley) is:   Flash point = 0.77(ASTM 5% in oF - 150oF).

However, the author claims that the IndianOil Kandla Laboratory team work is more accurate than the other existing known correlation equations, though work done much earlier then, with following features:

It is most accurate, 2 parameters ( IBP  and 10%T ) have been correlated rather than one.   Flash Point of the sample can be predicted accurately from routine Distillation data. When Distillation data are very accurate, the flash point worked out is within precision of the test methods. Also from Flash point, prediction of either IBP or T10 can be made accurately.  This was used extensively for verifying data in many round robin programmes conducted by IndianOil Laboratories.

Performance of equipment/technicians, indirectly verifying accuracy of thermometers, test protocol followed by technician etc is possible. A caution is not out of place that any contaminated samples with volatile products like gasoline will have error like result.

Author acknowledges other team members for their contribution for the efforts towards deriving most accurate relationship equation between Flash point and front end routine distillation data.  Hope the Petroleum technical community will be benefited by use of the equation. 

References :

http://www.eng-tips.com/viewthread.cfm?qid=178623 

Key Words :  Flash Point Abel,  Distillation D-86,

Follow me on twitter @RJPatel13 to get notification when my new post is available in my blog.



****************************************************************************

Comments

Anonymous said…
Checked for Jet A1 and SKO samples recently and works well.
Anonymous said…
Any limitation to the published equation ?

Popular posts from this blog

- Excel Formula-Density Conversion to 15 deg C, table ASTM 53 B - 1980,

- Temperature around 15 deg C, - Density Conversion for Petroleum Products from observed temperature to 15 C without use of ASTM Table (1980 series)

Density conversion to any temperature say 20 C, 15 C or any desired temperature from any observed temp

Android/iOS apps for Petroleum Calculation